564 Space Saver FireplaceTested and Listed byOMNI-Test Laboratories, Inc.Beaverton, OregonReport # 028-F-80-5ANSI Z21.88b-2003• Built-In Direct Vent
10 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Top Vent or Rear Vent ConfigurationThis appliance is shipped in
Installation (for qualified installers only) 11© Travis Industries 4070620 100-01188_000Converting the Fireplace to Top Vent (continued)Remove the 4
12 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Fireplace Placement Requirements• The fireplace requires a 1/2
Installation (for qualified installers only) 13© Travis Industries 4070620 100-01188_000Minimum Framing Dimensions - Rear Vent Configuration24-1/4&qu
14 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Minimum Framing Dimensions - Top Vent ConfigurationRoute the el
Installation (for qualified installers only) 15© Travis Industries 4070620 100-01188_000Nailing BracketsNOTE: Additional nailing brackets are provide
16 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Corner Installations - Rear Vent ConfigurationA typical 45° ins
Installation (for qualified installers only) 17© Travis Industries 4070620 100-01188_000Corner Installations - Top Vent ConfigurationA typical 45° in
18 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Gas Line RequirementsMASSACHUSETTS INSTALLATIONS - WARNIN
Installation (for qualified installers only) 19© Travis Industries 4070620 100-01188_000Gas Line Location13-1/2"6"13-1/2"6"The ga
2 Introduction© Travis Industries 4070620 100-01188_000OverviewThis manual details the installation requirements forthe 564 SS fireplace. For operati
20 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Electrical Connection (required)• The electrical line to the g
Installation (for qualified installers only) 21© Travis Industries 4070620 100-01188_000Wall Switch or Thermostat InstallationWiring Diagram (Millivo
22 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Vent Requirements• The gas appliance and vent system must be v
Installation (for qualified installers only) 23© Travis Industries 4070620 100-01188_000Approved Vent• Rear vent configurations use 8" diameter
24 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Approved Vent ConfigurationsRestrictor Position• Intake and ex
Installation (for qualified installers only) 25© Travis Industries 4070620 100-01188_000Intake Restrictor AdjustmentLoosen the two screws holding the
26 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Diffuser Plate AdjustmentCertain vent configurations require th
Installation (for qualified installers only) 27© Travis Industries 4070620 100-01188_000Rear Vent Configuration with Horizontal Termination (no verti
28 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Rear Vent Configuration with Horizontal Termination (with verti
Installation (for qualified installers only) 29© Travis Industries 4070620 100-01188_000Rear Vent Configuration with Vertical Termination• The termi
Table of Contents 3© Travis Industries 4070620 100-01188_000IntroductionOverview...2List
30 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Top Vent Configuration with Horizontal Termination• The termin
Installation (for qualified installers only) 31© Travis Industries 4070620 100-01188_000Top Vent Configuration with Vertical Termination• The termin
32 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000 Termination RequirementsNOTE : Measure all clearances from t
Installation (for qualified installers only) 33© Travis Industries 4070620 100-01188_000Hearth RequirementsDo not build a hearth more than 1” above t
34 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Facing Requirements• This appliance is designed to allow for d
Installation (for qualified installers only) 35© Travis Industries 4070620 100-01188_000Facing OverviewUpgrade faces are available for this fireplace
36 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Thin Facing Installation (tile, marble, or other non-combustibl
Installation (for qualified installers only) 37© Travis Industries 4070620 100-01188_000Thin Facing Installation (tile, marble, under 1" thick)
38 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Thick Facing Installation (stone, brick, or other non-combustib
Installation (for qualified installers only) 39© Travis Industries 4070620 100-01188_000 Thick Facing with Fireplace Xtrordinair (FPX) Arched FacesTh
4 Safety PrecautionsTravis Industries 4070620 100-01188_000Safety Warnings:• Failure to follow all of the requirements may result in property damage,
40 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Thick Facing Installation - Side ViewSIDE OF FIREPLACEDrywallMa
Installation (for qualified installers only) 41© Travis Industries 4070620 100-01188_000Mantel Requirements• The illustration below details mantel c
42 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Installation Example - Build-Out (Dog-House) with Hor. Terminat
Installation (for qualified installers only) 43© Travis Industries 4070620 100-01188_000Installation Example - Build-In with Horizontal Termination•
44 Finalizing the Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Steps for Finalizing the Installation1. Remove
Finalizing the Installation (for qualified installers only) 45© Travis Industries 4070620 100-01188_0008. Check the air shutter following the direct
46 Finalizing the Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Glass Frame Removal and InstallationWarning: The
Finalizing the Installation (for qualified installers only) 47© Travis Industries 4070620 100-01188_000Glass Frame Removal and Installation (continue
48 Finalizing the Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Log Set InstallationLog Set OverviewWhen install
Finalizing the Installation (for qualified installers only) 49© Travis Industries 4070620 100-01188_000Rear Log InstallationPlace the rear log on the
Safety Precautions 5© Travis Industries 4070620 100-01188_000Safety Warnings (continued):• Allow the heater to cool before carrying out any maintenan
50 Finalizing the Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Right Log InstallationNote how the right side of
Finalizing the Installation (for qualified installers only) 51© Travis Industries 4070620 100-01188_000Left Log InstallationThe left log has a groove
52 Finalizing the Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Left Twig InstallationThis hole fits over the pi
Finalizing the Installation (for qualified installers only) 53© Travis Industries 4070620 100-01188_000Right Twig InstallationThe right twig has twoh
54 Finalizing the Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Ember InstallationA bag of embers is provided to
Finalizing the Installation (for qualified installers only) 55© Travis Industries 4070620 100-01188_000LP Conversion InstructionsInstall the conversi
56 Finalizing the Installation (for qualified installers only)Travis Industries 4070620 100-01188_0003 Follow the directions below to replace the ori
Finalizing the Installation (for qualified installers only) 57© Travis Industries 4070620 100-01188_0004 Remove the pilot orifice following the instr
58 Finalizing the Installation (for qualified installers only)Travis Industries 4070620 100-01188_0007 Make the gas line connection, bleed the gas li
Optional Equipment (for qualified installers only) 59© Travis Industries 4070620 100-01188_000Fireback InstallationWARNINGTurn off gas to theapplianc
6 Features and SpecificationsTravis Industries 4070620 100-01188_000Installation Options• Residential or Mobile Home• Straight or Corner Placement•
60 Optional Equipment (for qualified installers only)Travis Industries 4070620 100-01188_000Blower (part # 99000156)Make sure power to the fireplace
Optional Equipment (for qualified installers only) 61© Travis Industries 4070620 100-01188_0002. Attach the blowers (use the #8 x 3/4" silver s
62 Optional Equipment (for qualified installers only)Travis Industries 4070620 100-01188_0003. Attach the wiring and rheostat assembly following the
Optional Equipment (for qualified installers only) 63© Travis Industries 4070620 100-01188_000Grill InstallationCertain faces allow for installation
64 Optional Equipment (for qualified installers only)Travis Industries 4070620 100-01188_000Remote Control Receiver Installation (2 Options)The instr
Optional Equipment (for qualified installers only) 65© Travis Industries 4070620 100-01188_000Accent Light Installation 94400100Make sure power to
66 Optional Equipment (for qualified installers only)Travis Industries 4070620 100-01188_000If using the optional fireback, install the rear fireback
Optional Equipment (for qualified installers only) 67© Travis Industries 4070620 100-01188_000If using the optional wall-mounted rheostat, follow the
68 Optional Equipment (for qualified installers only)Travis Industries 4070620 100-01188_000Optional Wall-Mounted Rheostat NOTE: Many areas require
Optional Equipment (for qualified installers only) 69© Travis Industries 4070620 100-01188_000Accent Light Operation OFFTurn the dial all the way c
Installation (for qualified installers only) 7© Travis Industries 4070620 100-01188_000Packing List• Propane Conversion Kit• Log Set• Wall Switch
70 IndexTravis Industries 4070620 100-01188_000IndexAdditional Items Required ...7Air Shutter Adjustment ...
8 Installation (for qualified installers only)Travis Industries 4070620 100-01188_000Massachusetts RequirementsNOTE: The following requirements refer
Installation (for qualified installers only) 9© Travis Industries 4070620 100-01188_000Top Stand-Off AssemblyThe top stand-offs must be assembled pri